HX04 Medical High Frequency X-ray Machine
The HX04 Medical High Frequency X-ray Machine is a reliable and efficient radiography system designed for modern clinical and hospital environments. Built with advanced high-frequency technology, it ensures stable output, precise exposure control, and consistent image quality across a wide range of diagnostic applications.
The system is engineered for versatility, supporting imaging of the head, chest, abdomen, and extremities. Its integrated configuration—comprising a high-voltage generator, X-ray tube, radiography table, and support stand—provides a complete and dependable solution for general radiography needs.
With fast image acquisition, DICOM compatibility, and seamless integration with hospital systems such as HIS, RIS, and PACS, the HX04 enhances workflow efficiency while maintaining high diagnostic accuracy. Its robust construction and flexible movement capabilities make it suitable for both routine examinations and high-demand clinical settings.
feature:Title|Description or use the custom.benefits metafield for automatic feature generation.The HX04 Medical High Frequency X-ray Machine is a reliable and efficient radiography system designed for modern clinical and hospital environments. Built with advanced high-frequency technology, it ensures stable output, precise exposure control, and consistent image quality across a wide range of diagnostic applications.
The system is engineered for versatility, supporting imaging of the head, chest, abdomen, and extremities. Its integrated configuration—comprising a high-voltage generator, X-ray tube, radiography table, and support stand—provides a complete and dependable solution for general radiography needs.
With fast image acquisition, DICOM compatibility, and seamless integration with hospital systems such as HIS, RIS, and PACS, the HX04 enhances workflow efficiency while maintaining high diagnostic accuracy. Its robust construction and flexible movement capabilities make it suitable for both routine examinations and high-demand clinical settings.
| Specifications | |
| System & Power | |
| Output Power | 32 kW |
| Power Supply | Single-phase 220V (3 wires) / Three-phase 380V ±38V |
| Nominal Frequency | ≥30 kHz |
| Function | Radiography |
| X-ray Tube & Generator | |
| Tube Current Range | 16 mA – 200 mA / up to 400 mA |
| Tube Voltage Range | 40 kV – 125 kV |
| Anode Speed | 2800 r/min |
| Anode Heat Capacity | 140 KHU |
| Focus Size | Small 1.0 mm / Large 2.0 mm |
| Exposure Parameters | |
| Exposure Time | 0.0025 s – 6.4 s |
| Output Voltage | 40 – 125 kV (1 kV step) |
| Maximum Output (Intermittent) | 100 kV / 200 mA / 20 kW |
| Mechanical & Movement | |
| Table Size | 2100 mm × 825 mm × 650 mm |
| Horizontal Movement Range | ≥250 mm |
| Vertical Movement Range | ≥825 mm |
| Focus Distance | 100 cm |
| Grid & Imaging | |
| Grid Density | ≥40 lines/cm |
| Grid Ratio | 10:1 |
| Cassette Size | 5″×7″, 8″×10″, 10″×12″, 11″×14″, 14″×17″ |
| Flat Panel Detector (Optional) | |
| Detector Type | TFT (a-Si / GOS) Photodiode |
| Detector Size | 14″×17″ / 17″×17″ |
| Pixel Matrix | Up to 3072 × 3072 |
| Limiting Resolution | 3.4 lp/mm |
| Pixel Pitch | ≤140 µm |
| A/D Conversion | 16 bits |
| Image Acquisition Time | < 2 seconds |
| Weight | 3.5 kg – 5.5 kg |
| System & Software | |
| PACS Integration | Supported |
| DICOM | DICOM 3.0 compliant |
| Synchronization | AED technology |
| Workstation | Intel CPU ≥3.5 GHz, RAM ≥4 GB, Storage ≥500 GB |
| Languages | English, French, Spanish, Arabic |
| Environmental Conditions | |
| Operating Temperature | -20°C to +70°C |
| Humidity | 10% – 100% (with condensation) |
| Atmospheric Pressure | 50 kPa – 106 kPa |
| Configuration | |
| Includes | |
| High-frequency high-voltage generator (with control console) | |
| X-ray tube | |
| Radiography table | |
| Supporting frame with electromagnetic brake | |
| Collimator (AC 24V) |